• Ammonia Nitrogen Analyzer, Based on Salicylic Acid Spectrophotometry Principle, High Accurancy
  • Ammonia Nitrogen Analyzer, Based on Salicylic Acid Spectrophotometry Principle, High Accurancy
  • Ammonia Nitrogen Analyzer, Based on Salicylic Acid Spectrophotometry Principle, High Accurancy
  • Ammonia Nitrogen Analyzer, Based on Salicylic Acid Spectrophotometry Principle, High Accurancy
  • Ammonia Nitrogen Analyzer, Based on Salicylic Acid Spectrophotometry Principle, High Accurancy
  • Ammonia Nitrogen Analyzer, Based on Salicylic Acid Spectrophotometry Principle, High Accurancy

Ammonia Nitrogen Analyzer, Based on Salicylic Acid Spectrophotometry Principle, High Accurancy

Warranty: 12 Months
Display: Digital
Appliance: Water Quality Online Monitoring
Portable: Non Portable
Certification: CE
Type: Water Quality Online Monitoring
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
WDet-7000 Ammonia Nitrogen
Transport Package
Wooden Box Packaging
Specification
30Kg
Trademark
YUAN ZHENG
Origin
China
Production Capacity
> 5000 Units/Year

Product Description


WDet-7000 Ammonia Nitrogen Online Analyzer
WDet-7000 Ammonia Nitrogen Online Analyzer is develped based on the global initiative magnetic conductivity measurement platform, combining with constant optical fiber and digestion colorimetric integration technology. The ammonia-nitrogen analyzer has the features, including high precision, low detection limit, high stability and low maintenance frequency. This ammonia-nitrogen analyzer works in accordance with the technical requirements of HJ/T 536-2009 Water Quality Ammonia-Nitrogen Measurement-Salicylic Acid Method, fully meets the pollution sources, municipal wastewater, industrial processes in the application areas, and has passed the certification of CMC and CCEP

Features:
High accuracy and reliability, strong capability of anti-interference
• Magnetic conductivity measurement technology, not be affected by chromaticity, suspended solids, and bubbles, especially suitable for the monitoring of inlet water
• Strong anti-interference ability to color resistance and calcium and magnesium ion
• Special design of flow and reagent ratio, high precision, low detection limit(0.01mg/L)
• Constant optical fiber and light intensity compensation algorithm, small drift for long-term operation

Easy operation & Low maintenance
• Self-check function, easy to debug, maintain, comparison test
• Self-diagnosis function, assisting maintainer to analyze the failure
• Imported single-channel high integration valve island, simple and easy to maintain, dismantle and clean
• All-day networking for real-time inspection of instrument running state

High intelligent level
• Scan code function: rapidly obtain running/maintenance information of the the analyzer
• Alarm function: this analyzer provides intuitive and accurate information for grounding self-check, reagent insufficiency and etc
• Great quality control: equipped with a parallel sample test, standard sample verification, and standard recovery rate detection
• Reverse control function: this analyzer starts automatically by flow and PH

Specification:
Measuring method: Salicylic Acid Spectrophotometry
Range: 0~2/10/100mg/L (extensible
Indication error: ±10%
Repeatability: ≤3%
Zero drift: 0.02 mg/l
Span drift: <1%F.S.
Memory effect: 20%F.S. ±0.3mg/L;
80%F.S. ±0.2mg/L;
LLOQ:  0.01mg/L
Quality Control Sample Comparison: ±10%
Reagent: 1 set reagents is able for about 250 times of measurement (can be customized according to field needs
Maintenance: <2 hours/month
Ambient temperature: 5ºC~40ºC
Communication interface: RS485/RS232/USB interface (optional)
1x4-20mA input/output (can be expanded to 2)
Power consumption: 200W(220±10%VAC 50Hz), without sampling pump
Note: test method refers to the latest standards of Environmental Certification
 
Ammonia Nitrogen Analyzer, Based on Salicylic Acid Spectrophotometry Principle, High Accurancy

Application
Ammonia Nitrogen Analyzer, Based on Salicylic Acid Spectrophotometry Principle, High Accurancy
About us

Ammonia Nitrogen Analyzer, Based on Salicylic Acid Spectrophotometry Principle, High AccurancyAmmonia Nitrogen Analyzer, Based on Salicylic Acid Spectrophotometry Principle, High AccurancyAmmonia Nitrogen Analyzer, Based on Salicylic Acid Spectrophotometry Principle, High AccurancyWorkshop
Ammonia Nitrogen Analyzer, Based on Salicylic Acid Spectrophotometry Principle, High Accurancy

Ammonia Nitrogen Analyzer, Based on Salicylic Acid Spectrophotometry Principle, High Accurancy

Q&A:Ammonia Nitrogen Analyzer, Based on Salicylic Acid Spectrophotometry Principle, High Accurancy

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
30000000 RMB
Plant Area
101~500 square meters