Customization: | Available |
---|---|
After-sales Service: | 12 Months |
Warranty: | 12 Months |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
General | |
Measuring principle | SO2, NOx : UV-DOAS |
O2: Electrochemistry or Zirconia (option) | |
CO: NDIR | |
CO2: Infrared NDIR Technology | |
Measurement component and range | Measurement components and range can be customized. Standard range : SO2, : (0~3500) ppm NO:(0~500) ppm CO:(0~750) ppm CO2:(0~20)% vol O2:(0~25)% vol |
Analog input signal | 3×DC4~20mA, configurable |
Analog output signal | 5×DC4~20mA, configurable |
Digital input | 6, configurable |
Relay output | 14, configurable |
Communication interface | RS232 / RS485 |
Power supply | Rated voltage: AC(220±22)V |
Rated power: 200W | |
AC frequency: (50±1)Hz | |
Operating conditions | Ambient temperature: 0~40 ℃ Ambient humidity: < 93%RH, non-condensing |
Outline dimension | 483mm ×503mm ×177mm(W×D×H) |
Net weight | 27 Kg |
Gross weight | 33.5 Kg |
Performance | |
Repeatability | ≤2% |
Stability | ≤5% |
Zero drift | ≤±2%FS (24h) or ≤±3%FS (7d) |
Span drift | ≤±2%FS (24h) or ≤±3%FS (7d) |
Response time | ≤90s |
Standard gas condition | |
Flow | 2L/min |
Pressure | Current ambient pressure ±0.1 bar |
Temperature | 0~40 ℃ |
Humidity | <85% RH, non-condensing |
Calibration gas | Zero gas: dry N2 or air. If using zirconia oxygen measurement module, nitrogen can not be used for zeroing. Span gas: 80~100% of the measured component range (recommended, concentration more than 100% should not be used. |
Function | |
Automatic span calibration (customizable) | • Periodic auto calibration based on the preset cycle Automatic calibration cycle setting range:1~60,000 hours • Injection time of each calibration gas can be set during automatic calibration. Pre-purge time and post-purge time:1~300s. |
Zeroing | • Periodic auto calibration based on the preset cycle Automatic calibration cycle setting range:1~60,000 hours • Injection time of each calibration gas can be set during automatic calibration. Pre-purge time and post-purge time:1~300s. |
Upper and lower limit alarm | The alarm will be trigged when the measured value reaches upper and lower alarm limits. The analyzer will send alarm signals when the measured concentration of each component is beyond the preset upper/lower alarm limit. |