• Portable Gas Analyzer for Emission Detection of Fixed Sources, Optical Length up to 13m
  • Portable Gas Analyzer for Emission Detection of Fixed Sources, Optical Length up to 13m
  • Portable Gas Analyzer for Emission Detection of Fixed Sources, Optical Length up to 13m
  • Portable Gas Analyzer for Emission Detection of Fixed Sources, Optical Length up to 13m
  • Portable Gas Analyzer for Emission Detection of Fixed Sources, Optical Length up to 13m
  • Portable Gas Analyzer for Emission Detection of Fixed Sources, Optical Length up to 13m

Portable Gas Analyzer for Emission Detection of Fixed Sources, Optical Length up to 13m

Warranty: 12 Months
Brand: Yuan Zheng
Customized: Non-Customized
Portable: Non Portable
Certification: CE
Gas: So2, Nox (No, No2), CH4, Nh3, HCl, Hf, Co, CO2, O2
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
FT-2000P
Type
Infrared Absorption Analyzer
Transport Package
Carbon Box
Specification
20 Kg
Trademark
YUAN ZHENG
Origin
China
Production Capacity
>1000 Units/Year

Product Description

FT-2000P FTIR Gas Analyzer
Based on FTIR technology, FT-2000P portable gas analyzer can continuously monitor various kinds of components in the emission, such as SO2, NOx(NO, NO2),CH4, NH3, HCl, HF, CO, CO2, O2, H2O. According to actual measuring need, it can be extended to measure other components, like SO3, N2O and etc. This portable system mainly comprises FTIR analyzer and sampling probe. It has features of high measurement accuracy, wide dynamic range and low detection limit.


Feature
  1. Warming up is no required for the analyzer to realize fast measurement;
  2. Applicable for high humidity and dust occasion
  3. Optical length up to 13m, extremely low detection limit, high range dynamics, satisfy the monitoring of small emission limit;
  4. By applying OLS and PLS techniques and selecting, interference from H2O or others can be effectively eliminated;
  5. Quick site sampling, analysis and easy operation.

Application
*  Emission detection of fixed sources,
*  CEMS comparison and acceptance,
*  Emergency monitoring,
*  laboratory measurement analysis


Specification
principle: fourier transform infrared spectroscopy (FTIR)
Range: SO2: (0~75) mg/m3
NO: (0~200) mg/m3
NO2: (0~40) mg/m3
NOx: (0~200) mg/m3
CO: (0~75) mg/m3
H2O: (0~40) %
CH4: (0~20) mg/m3
NH3: (0~10) mg/m3
HCl: (0~15) mg/m3
HF: (0~10) mg/m3
CO2: (0~20) mg/m3
Pretreatment Method: condensation dewatering/whole process high temperature (optional)
Repeatability: ≤2%
Zero Drift: ≤±2%F.S./24h
Span Drift: ≤±2%F.S./24h
Sampling Flow: (1.5±0.5) L/min
Response Time: ≤90s (T90)
Enclosure Protection: IP41
Working Temp.: 0~45ºC
Working Pressure: 80kPa~106kPa
Humidity: 0~95%RH
Communication: RS232&USB


Portable Gas Analyzer for Emission Detection of Fixed Sources, Optical Length up to 13m
Portable Gas Analyzer for Emission Detection of Fixed Sources, Optical Length up to 13mPortable Gas Analyzer for Emission Detection of Fixed Sources, Optical Length up to 13mPortable Gas Analyzer for Emission Detection of Fixed Sources, Optical Length up to 13mPortable Gas Analyzer for Emission Detection of Fixed Sources, Optical Length up to 13mPortable Gas Analyzer for Emission Detection of Fixed Sources, Optical Length up to 13mPortable Gas Analyzer for Emission Detection of Fixed Sources, Optical Length up to 13m

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
30000000 RMB
Plant Area
101~500 square meters