High-Temperature Heat Tracing Extraction Dust Monitor, Low Detection Limit (as low as 0.05mg/m3) , No Interference by Moisture, High Measurement Accuracy

Product Details
Customization: Available
Warranty: 12 Months
Brand: Yuan Zheng
Still deciding? Get samples of US$ 3000/Piece
Request Sample
Manufacturer/Factory, Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
30000000 RMB
Plant Area
101~500 square meters
  • High-Temperature Heat Tracing Extraction Dust Monitor, Low Detection Limit (as low as 0.05mg/m3) , No Interference by Moisture, High Measurement Accuracy
  • High-Temperature Heat Tracing Extraction Dust Monitor, Low Detection Limit (as low as 0.05mg/m3) , No Interference by Moisture, High Measurement Accuracy
  • High-Temperature Heat Tracing Extraction Dust Monitor, Low Detection Limit (as low as 0.05mg/m3) , No Interference by Moisture, High Measurement Accuracy
  • High-Temperature Heat Tracing Extraction Dust Monitor, Low Detection Limit (as low as 0.05mg/m3) , No Interference by Moisture, High Measurement Accuracy
  • High-Temperature Heat Tracing Extraction Dust Monitor, Low Detection Limit (as low as 0.05mg/m3) , No Interference by Moisture, High Measurement Accuracy
  • High-Temperature Heat Tracing Extraction Dust Monitor, Low Detection Limit (as low as 0.05mg/m3) , No Interference by Moisture, High Measurement Accuracy
Find Similar Products

Basic Info.

Model NO.
DMT-300
Customized
Non-Customized
Portable
Non Portable
Certification
CE
Gas
So2, Nox (No, No2), CH4, Nh3, HCl, Hf, Co, CO2, O2
Type
Laser Gas Analyzer
Transport Package
Carbon Box
Specification
15 Kg
Trademark
YUAN ZHENG
Origin
China
Production Capacity
>1000 Units/Year

Product Description

DMT-300 Dust monitor

DMT-300 dust monitor is a self-developed high-temperature heat tracing extraction dust monitor, based on years of technology research and development for dust detection. Different from conventional in-situ scattering dust monitor, DMT-300 extracts dust from flue (stack) in uniform speed to dust measurement module with full-process high-temperature heat tracing for measurement. It owns features of low detection limit (as low as 0.05mg/m3), no interference by moisture, high measurement accuracy, and etc. It applies to low temperature and high humidity dust conditions of super clean emission and after wet desulphurization.


Application
The  DMT-300 dust particle measuring device is widely applied in enterprises including thermal power, ferrous metallurgy, petrochemical industry, cement production, potting, waste incineration; flue gas emission monitoring in all kinds of power generating boiler, industrial kiln, and industrial boiler; monitoring and control in gas desulphurization and dust removal process.


Feature
•    Adopt the laser forward scattering method to detect dust concentration; low detection limit.
•    Full-process heat tracing, which heats water vapor to the gaseous state to prevent dust from caking and blocking gas path when encountering water. Thus it applies to high humidity occasion.
•    Pitot tube isokinetic sampling method meets the technical condition of dust sampling
•    Support automatic purging to clean gas path and avoid dust blocking
•    Support automatic zeroing technology under high temperature and automatic calibration technology of all optical paths
•    Support on-site manual span calibration
•    Support automatic double-range switching



Working principle

Under the negative pressure effect of the jet pump, dust in the stack enters the measurement module after being heated by tracing the sampling probe. Heat tracing will be in the whole process of extraction, measurement, and emission to eliminate moisture interference and prevent dust from blocking the gas path if encountering condensate water. The dust after being heated enters the measurement module, where the laser forward scattering dust monitor principle is used to measure dust concentration. After the measurement, the exhaust gas goes into the stack again.

DMS-300 manufactured by ZETIAN, one of the best 
continuous emission monitoring system suppliers, employs a magnetic valve and control unit to realize the automatic purging of the gas path and measurement module. Automatic zeroing shall be performed termly.  After maintenance, close laser device and insert calibration module for manual zeroing and calibration. Micro differential pressure transmitter and pitot tube are used to measure gas velocity in stack and feedback to the flow-control device at the same time. It can realize isokinetic sampling and isokinetic flue dust extraction for measurement of pitot tube by changing the jet gas flow to control extraction velocity.



Composition
High-Temperature Heat Tracing Extraction Dust Monitor, Low Detection Limit (as low as 0.05mg/m3) , No Interference by Moisture, High Measurement Accuracy
 
The extraction dust monitor is composed by jet gas control unit (1, 2),  measurement unit (3, 4, 5, 8, 9), control & display unit (7),  and gas path control unit (6,10, 11, 12).   The flue gas inside stack is extracted to measurement unit in constant speed by gas path control unit. Measurement unit is with full-process high temperature tracing to eliminate influence from moisture to dust measurement. Actual concentration signal is processed and displayed by control &display unit. The gas control unit is able to achieve flue gas isokinetic extraction and reflect real dust concentration through velocity measurement inside stack, extraction velocity measurement of gas path, and velocity valve adjustment.The extraction dust monitor is composed of a jet gas control unit (1, 2),  measurement unit (3, 4, 5, 8, 9), control & display unit (7),  and gas path control unit (6,10, 11, 12).   The flue gas inside stack is extracted to the measurement unit at a constant speed by the gas path control unit. Measurement unit is with full-process high temperature tracing to eliminate influence from moisture to dust measurement. The actual concentration signal is processed and displayed by the control &display unit. The gas control unit is able to achieve flue gas isokinetic extraction and reflect real dust concentration through velocity measurement inside the stack, extraction velocity measurement of the gas path, and velocity valve adjustment.


Specification
Measurement Data
MeasuringPrinciple Laser forward scattering
MeasuringRange 0~20mg/m3, 0~50mg/m3 (customizable)
Detection Lower Limit 0.05mg/m3
IndicationError ±20%
Indication Error Repeatability ±10%
Response Time 2s (optional)
Laser Device 650nm, 20mW
Measurement Condition
Sampling Head Diameter 6mm, 8mm, 10mm, 12mm (customize according to working condition)
Heat Tracing Temperature 120ºC~180ºC
Medium Temperature <300ºC
Ambient Temperature -20ºC~+50ºC
Compressed Air No water and oil,≥0.4MPa, gas consumption 100L/min
Purging Time Purge 3min (concentration data keeps), interval period 4h (adjust according to working condition )
Velocity Range (2~40)m/s
Preheating Time 15min
Input, Output and Interface
Analog Output 4-20mA, maximum load 500Ω
Communication Interface Rs485, RS232 (optional)
General Information
Weight 103kg
Dimension 1620mm(H)* 850mm(L)* 264mm(D)
Power 1500W
Supply 220VAC

High-Temperature Heat Tracing Extraction Dust Monitor, Low Detection Limit (as low as 0.05mg/m3) , No Interference by Moisture, High Measurement Accuracy

High-Temperature Heat Tracing Extraction Dust Monitor, Low Detection Limit (as low as 0.05mg/m3) , No Interference by Moisture, High Measurement Accuracy

High-Temperature Heat Tracing Extraction Dust Monitor, Low Detection Limit (as low as 0.05mg/m3) , No Interference by Moisture, High Measurement AccuracyHigh-Temperature Heat Tracing Extraction Dust Monitor, Low Detection Limit (as low as 0.05mg/m3) , No Interference by Moisture, High Measurement AccuracyHigh-Temperature Heat Tracing Extraction Dust Monitor, Low Detection Limit (as low as 0.05mg/m3) , No Interference by Moisture, High Measurement AccuracyHigh-Temperature Heat Tracing Extraction Dust Monitor, Low Detection Limit (as low as 0.05mg/m3) , No Interference by Moisture, High Measurement Accuracy

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed